Arbitrary Function Generator
AFG-2000 Series
QUICK START GUIDE
GW INSTEK PART NO. 82AF-21200MC1
ISO-9001 CERTIFIED MANUFACTURER
Vista de página 0
1 2 3 4 5 6 ... 24 25

Resumo do Conteúdo

Página 1 - Arbitrary Function Generator

Arbitrary Function Generator AFG-2000 Series QUICK START GUIDE GW INSTEK PART NO. 82AF-21200MC1 ISO-9001 CERTIFIED MANUFACTURER

Página 2

AFG-2000 Quick Start Guide 8 Panel Overview AFG-2105/2112/2125 Front Panel ARBOUTPUT50W50WSYNCMAINOUTPUTPOWERSave/Recall INT/EXT Hop LIN/LOGShape

Página 3 - Table of Contents

GETTING STARTED 9 LCD display 3.5 inch, 3 color LCD display. Keypad 0/32147 8596 The digital keypad is used to enter values and parameters. The k

Página 4 - SAFETY INSTRUCTIONS

AFG-2000 Quick Start Guide 10 Operation keys Hz/Vpp Selects Hz or Vpp units. Shift+Save/RecallHz/Vpp Saves or recalls waveforms from memory. kHz

Página 5 - Safety Guidelines

GETTING STARTED 11 Sweep Selects the Sweep function*. Shift+Start/StopSweep Sets the Start or Stop frequency*. Count Turns the frequency counter o

Página 6

AFG-2000 Quick Start Guide 12 AFG-2105/2112/2125 Rear Panel NO OPERATOR SERVICEABLE COMPONENTS INSIDE.DO NOT REMOVE COVERS. REFER SERVIC

Página 7

GETTING STARTED 13 Display Waveform typeCounter settingsUSB iconFrequency displaySecondary parameter displayModulation, sweep, counter menu Wavef

Página 8 - GETTING STARTED

AFG-2000 Quick Start Guide 14 Selecting a Waveform Sine Wave Example: Sine Wave, 10kHz, 1Vpp, 2Vdc Output 50WMAIN 1. Press FUNC>select the s

Página 9

GETTING STARTED 15 ARB ARB – Enter Points Example: ARB Ramp, 10 kHz, 1Vpp, 2 points. Output 50WMAIN 1. Press FUNC>select the ARB wave 2.

Página 10 - Panel Overview

AFG-2000 Quick Start Guide 16 FM (2100 series only) Example: FM modulation. 100Hz modulating square wave. 1Vpp, 1kHz Sine wave carrier. 100 Hz f

Página 11 - High Z/50Ω

GETTING STARTED 17 Sweep (2100 series only) Example: Frequency Sweep. Start Frequency 1Hz, Stop Frequency 1MHz. 1Hz Rate. 1Vpp. Lins Sweep. Outp

Página 12

This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual may be photocopied,

Página 13 - Start/Stop

AFG-2000 Quick Start Guide 18 Save/Recall Save Example: Save waveform to memory. 1. Press Shift>Save/Recall>Select Save 2. Turn the S

Página 14 - Counter input

GETTING STARTED 19 AFG-2000 Series Specifications The specifications apply when the function generator is powered on for at least 30 minutes under

Página 15 - Display

AFG-2000 Quick Start Guide 20 Offset Range ±5 Vpk ac +dc (into 50Ω) ±10Vpk ac +dc (Open circuit) ±2.5 Vpk ac +dc (into 50Ω) for 20MHz-25MHz ±5Vpk

Página 16 - Selecting a Waveform

GETTING STARTED 21 AM Modulation Carrier Waveforms — Sine, Square, Triangle Modulating Waveforms — Sine, Square, Triangle Modulating Frequenc

Página 17 - Modulation

AFG-2000 Quick Start Guide 22 Frequency Counter Range — 5Hz to 150MHz Accuracy — Time Base accuracy±1count Time Base — ±20ppm (23˚C ±5˚C) af

Página 18 - FM (2100 series only)

GETTING STARTED 23 EC Declaration of Conformity We GOOD WILL INSTRUMENT CO., LTD. No.7-1, Jhongsing Rd., Tucheng Dist., New Taipei City 236, Tai

Página 19 - Counter (2100 series only)

TABLE OF CONTENTS 1 Table of Contents SAFETY INSTRUCTIONS ... 2 GETTING STARTED ...

Página 20 - Save/Recall

AFG-2000 Quick Start Guide 2 SAFETY INSTRUCTIONS This chapter contains important safety instructions that should be followed when operating and s

Página 21 - GETTING STARTED

SAFETY INSTRUCTIONS 3 Double Insulated Do not dispose electronic equipment as unsorted municipal waste. Please use a separate collection facilit

Página 22

AFG-2000 Quick Start Guide 4 Fuse WARNING  Fuse type: F1A/250V.  Only qualified technicians should replace the fuse.  To ensure fire prot

Página 23

SAFETY INSTRUCTIONS 5 precipitation, and full wind pressure, but neither temperature nor humidity is controlled. Storage environment  Location:

Página 24

AFG-2000 Quick Start Guide 6 GETTING STARTED The Getting started chapter introduces the function generator’s main features, appearance and introd

Página 25

GETTING STARTED 7 ARB       USB Interface       Performance  DDS technology using an FPGA provides high resolution waveforms  25M