Gw-instek APS-1102 User Manual Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Equipamento Gw-instek APS-1102 User Manual. GW Instek APS-1102 User Manual User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - USER MANUAL

 Programmable AC/DC Power Source APS-1102 USER MANUAL GW INSTEK PART NO. 82PS-11020M01 ISO-9001 CERTIFIED MANUFACTURER

Página 2

APS-1102 Programmable AC/DC Power Source viiiFigures Figure 1-1. Block Diagram...

Página 3 -  Preface 

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-364.4.4 Control of sequence operations The CONTROL item in the SEQUENC

Página 4 -  Safety Precautions 

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-37b) When operating with the shortcut keys  Operation step The contro

Página 5

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-384.4.5 Clear sequence memory Data is saved to sequence memory automat

Página 6 - Contents

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-394.4.6 Example of sequence operation settings The following describes

Página 7

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-40The operation steps are described below.  Operation steps using c

Página 8

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-416. Press the key to move the cursor to the line displaying “CONST”

Página 9

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-42 Setting step 2 10. Press the or key to move the cursor to “STE

Página 10 - Figures

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-434.4.7 Execution of sequence operations Once sequence programming has

Página 11

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-444. Press the ENTER key to display the selection box. ENTERCANCEL

Página 12

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-458. Press the key to select “CONTROL”, then press the ENTER key to di

Página 13

Figures APS-1102 Programmable AC/DC Power Source ixFigure 5-1. LCD Screen (When Normal) ...

Página 14

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-46c) Operations after starting sequence When a sequence is started, the

Página 15 - OVERVIEW

4.5 Control Using External Control I/O Connector APS-1102 Programmable AC/DC Power Source 4-474.5 Control Using External Control I/O Connector Di

Página 16 - 1.2 Features

4.6 Output of Arbitrary Waveforms APS-1102 Programmable AC/DC Power Source 4-484.6 Output of Arbitrary Waveforms Arbitrary waveforms are generated

Página 17 - 1.3 Applications

4.6 Output of Arbitrary Waveforms APS-1102 Programmable AC/DC Power Source 4-492. Press the or key to move the cursor to the arbitrary waveform

Página 18 - 1.4 List of Functions

4.7 Synchronization of Output to External Signal APS-1102 Programmable AC/DC Power Source 4-504.7 Synchronization of Output to External Signal The

Página 19

4.7 Synchronization of Output to External Signal APS-1102 Programmable AC/DC Power Source 4-514.7.1 External signal synchronization This functio

Página 20 - 1.5 Operation Principles

4.7 Synchronization of Output to External Signal APS-1102 Programmable AC/DC Power Source 4-524. Press the ENTER key to select the mode to be set.

Página 21 - PREPARATIONS BEFORE USE

4.8 Using Memory Functions APS-1102 Programmable AC/DC Power Source 4-534.7.2 Line synchronization This function synchronizes the output frequenc

Página 22 - 2.1 Checking Before Use

4.8 Using Memory Functions APS-1102 Programmable AC/DC Power Source 4-54 Memory control is performed via the “MEMORY” screen. After selecting an o

Página 23 -  Cautions for transport

4.8 Using Memory Functions APS-1102 Programmable AC/DC Power Source 4-55 Operation steps Select and then “MEMORY” in the MISC menu to store, re

Página 24

APS-1102 Programmable AC/DC Power Source xTables Table 1-1. List of Functions (1/2) ...

Página 25 - WARNING

4.8 Using Memory Functions APS-1102 Programmable AC/DC Power Source 4-564. Press the or key to select the operation to be performed. ENT

Página 26

4.9 Amplification of External Signal APS-1102 Programmable AC/DC Power Source 4-574.9 Amplification of External Signal The APS-1102 can be used as

Página 27

4.9 Amplification of External Signal APS-1102 Programmable AC/DC Power Source 4-58a) Possible voltage settings for output  Operation steps Sele

Página 28 - 2.4 Simple Operation Checks

4.9 Amplification of External Signal APS-1102 Programmable AC/DC Power Source 4-59the ENTER key.  This sets the selected output voltage range.

Página 29

4.9 Amplification of External Signal APS-1102 Programmable AC/DC Power Source 4-60b) Signal input The setup for external input is completed once th

Página 30 - 2.5 Calibration

4.10 Adding External Signals and Internal Signals APS-1102 Programmable AC/DC Power Source 4-614.10 Adding External Signals and Internal Signals

Página 32 - 3.1.1 Operation panel

APS-1102 Programmable AC/DC Power Source 5-15. MENUS 5.1 Screen Configuration ·······················································

Página 33 - 3.1.2 Front panel

APS-1102 Programmable AC/DC Power Source 5-25.6.1 Keylock ········································································· 5-38 5.6.2 Beep s

Página 34 - 3.1.3 Rear panel

5.1 Screen Configuration APS-1102 Programmable AC/DC Power Source 5-35.1 Screen Configuration The LCD on the control panel splits in m

Página 35 -  Initial settings

Tables APS-1102 Programmable AC/DC Power Source xiTable 5-11. SET Menu Items and Output Modes ...

Página 36 - At Power-on

5.1 Screen Configuration APS-1102 Programmable AC/DC Power Source 5-4The following information is displayed in various parts of the screen. A:

Página 37 - 3.3 I/O Terminals

5.1 Screen Configuration APS-1102 Programmable AC/DC Power Source 5-55.1.1 Status icons The status window displays status icons that indicate the

Página 38

5.1 Screen Configuration APS-1102 Programmable AC/DC Power Source 5-65.1.2 Warnings and error messages When a warning or error occurs, an error

Página 39

5.2 Basic Operations APS-1102 Programmable AC/DC Power Source 5-75.2 Basic Operations The APS-1102 basic operations are described below. 5.2.

Página 40 - 3.3.2 USB connector

5.2 Basic Operations APS-1102 Programmable AC/DC Power Source 5-8Table 5-3. Items in SET Menu Icon Item Reference Select output mode See “

Página 41 - 3.3.3 External control I/O

5.2 Basic Operations APS-1102 Programmable AC/DC Power Source 5-9Table 5-4. Items in MISC Menu Setting Name Setting Reference SEQUENCE Open s

Página 42

5.2 Basic Operations APS-1102 Programmable AC/DC Power Source 5-10Table 5-5. Items in SEQUENCE Menu Setting Name Setting Reference CONTROL...

Página 43 - External signal input/

5.2 Basic Operations APS-1102 Programmable AC/DC Power Source 5-11Table 5-7. Items in REMOTE Menu Setting Name Setting Reference LOCAL... S

Página 44 - 3.4 Main Operation Example

5.2 Basic Operations APS-1102 Programmable AC/DC Power Source 5-125.2.2 Navigating the menu tree Use the UP and DOWN keys to move among items dis

Página 45 - 3.4.1 Power on/off

5.2 Basic Operations APS-1102 Programmable AC/DC Power Source 5-135.2.3 Numerical value input operations When input of numerical values is requi

Página 46 - Output off

Tables APS-1102 Programmable AC/DC Power Source xiiTable 7-14. When Fault Is Suspected (Problem Related to Measurement Functions) ... 7

Página 47 - 3.4.2 Setting output mode

5.2 Basic Operations APS-1102 Programmable AC/DC Power Source 5-145.2.5 EXEC input The EXEC box is displayed for items to be actually executed b

Página 48

5.3 SET Menu APS-1102 Programmable AC/DC Power Source 5-155.3 SET Menu The SET menu in the menu window is used to set basic functions. The ava

Página 49

5.3 SET Menu APS-1102 Programmable AC/DC Power Source 5-165.3.1 Output mode setting Table 5-12 lists the eight output modes that can be selected

Página 50 - Status window

5.3 SET Menu APS-1102 Programmable AC/DC Power Source 5-17 Figure 5-7 shows a block diagram of the APS-1102 signal sources. Figure 5-7. Block

Página 51 - 3.4.4 Setting waveform

5.3 SET Menu APS-1102 Programmable AC/DC Power Source 5-185.3.3 Setting output voltage The output voltage settings listed below can be made for

Página 52

5.3 SET Menu APS-1102 Programmable AC/DC Power Source 5-195.3.4 Setting output frequency This sets the AC voltage frequency. When either AC-SY

Página 53

5.3 SET Menu APS-1102 Programmable AC/DC Power Source 5-205.3.7 Output peak current limiter settings The positive value and the negative value of

Página 54

5.3 SET Menu APS-1102 Programmable AC/DC Power Source 5-215.3.8 Output average current limiter settings This limits the output average current.

Página 55

5.4 MEASURE Screen APS-1102 Programmable AC/DC Power Source 5-225.4 MEASURE Screen The MEASURE screen in the measured value window displays meas

Página 56

5.4 MEASURE Screen APS-1102 Programmable AC/DC Power Source 5-235.4.1 Output voltage measurement When “MEASURE” has been selected in the MISC me

Página 57

APS-1102 Programmable AC/DC Power Source 1-11. OVERVIEW 1.1 General ...

Página 58 - Modification box

5.4 MEASURE Screen APS-1102 Programmable AC/DC Power Source 5-245.4.2 Output current measurement When “MEASURE” has been selected in the MISC me

Página 59 - Output on/off LED on

5.4 MEASURE Screen APS-1102 Programmable AC/DC Power Source 5-255.4.3 Output power measurement The output power values described below are alway

Página 60

5.4 MEASURE Screen APS-1102 Programmable AC/DC Power Source 5-265.4.6 Output harmonic current measurement Output harmonic current measurement is

Página 61

5.5 MISC Menu APS-1102 Programmable AC/DC Power Source 5-275.5 MISC Menu This menu is used to enter detailed settings for various functions. Th

Página 62

5.5 MISC Menu APS-1102 Programmable AC/DC Power Source 5-28b) PROGRAM (sequence programming) This “PROGRAM” screen is used to program sequences.

Página 63 - 3.5 Output Characteristics

5.5 MISC Menu APS-1102 Programmable AC/DC Power Source 5-29Table 5-21. PROGRAM Screen Items (2/3) Setting Name Item Operation FREQ AC frequen

Página 64 - Maximum output power = 750 W

5.5 MISC Menu APS-1102 Programmable AC/DC Power Source 5-30Table 5-22. PROGRAM Screen Items (3/3) Setting Name Item Operation STEP TERM Step

Página 65 - ADVANCED OPERATION EXAMPLE

5.5 MISC Menu APS-1102 Programmable AC/DC Power Source 5-315.5.2 Memory (MEMORY) The “MEMORY” screen is used to control memory. Settings saved

Página 66

5.5 MISC Menu APS-1102 Programmable AC/DC Power Source 5-325.5.3 Remote (REMOTE) The remote control connected via a USB interface can be used to

Página 67

5.5 MISC Menu APS-1102 Programmable AC/DC Power Source 5-335.5.5 Setting range limiter (LIMIT) The setting range limiter indicates the LIMIT scre

Página 68 - Selection box

1.1 General APS-1102 Programmable AC/DC Power Source 1-21.1 General The APS-1102 programmable AC/DC power source is a power source that can ou

Página 69

5.5 MISC Menu APS-1102 Programmable AC/DC Power Source 5-345.5.6 Selection of measurement display (MEASURE) Select the measured values to be disp

Página 70

5.5 MISC Menu APS-1102 Programmable AC/DC Power Source 5-355.5.8 Output on/off The APS-1102 output on/off setting can be entered using the OUTPU

Página 71

5.6 System Menu APS-1102 Programmable AC/DC Power Source 5-365.6 System Menu This menu is used to enter the following system settings for the AP

Página 72

5.6 System Menu APS-1102 Programmable AC/DC Power Source 5-373. Press the ENTER key to display the SYSTEM screen . ENTERCANCEL 4. Press t

Página 73

5.6 System Menu APS-1102 Programmable AC/DC Power Source 5-385.6.1 Keylock The APS-1102 is equipped with a function that prevents key input error

Página 74

5.6 System Menu APS-1102 Programmable AC/DC Power Source 5-395.6.2 Beep sound When the beep sound is on, a beep sounds when an incorrect operatio

Página 75

5.6 System Menu APS-1102 Programmable AC/DC Power Source 5-405.6.3 LCD contrast adjustment The LCD screen contrast level can be set to any of 100

Página 76

5.6 System Menu APS-1102 Programmable AC/DC Power Source 5-415.6.4 LCD display color setting The display color of the LCD screen on the control p

Página 77

5.6 System Menu APS-1102 Programmable AC/DC Power Source 5-425.6.5 Time unit setting The unit used to indicate the time parameter can be specifie

Página 78 - 4.2.1 Inrush current

5.6 System Menu APS-1102 Programmable AC/DC Power Source 5-435.6.6 Output on/off setting at power-on The APS-1102 can be set to automatically tur

Página 79

1.3 Applications APS-1102 Programmable AC/DC Power Source 1-3 Enables AC-superimposed DC output When in the AC+DC mode, an AC wave (sine wav

Página 80

5.6 System Menu APS-1102 Programmable AC/DC Power Source 5-445.6.7 External control input enable/disable setting External control input can be se

Página 81

5.6 System Menu APS-1102 Programmable AC/DC Power Source 5-455.6.8 Reset function This function resets all basic settings to their initial (fact

Página 83

APS-1102 Programmable AC/DC Power Source 6-16. USB INTERFACE 6.1 Setup for Use ·································································

Página 84

6.1 Setup for Use APS-1102 Programmable AC/DC Power Source 6-26.1 Setup for Use The APS-1102 can be controlled under the USB Test and Measurement

Página 85 - 4.4.1 Sequence operations

6.2 Command List APS-1102 Programmable AC/DC Power Source 6-36.2 Command List The APS-1102 command list is shown in Table 6-1 to Table 6-9 and IEE

Página 86

6.2 Command List APS-1102 Programmable AC/DC Power Source 6-4Table 6-2. Command List (MEASure Subsystem) Function Command Output current RMS valu

Página 87

6.2 Command List APS-1102 Programmable AC/DC Power Source 6-5Table 6-4. Command List (STATus Subsystem) Function Command Operation condition regi

Página 88

6.2 Command List APS-1102 Programmable AC/DC Power Source 6-6Table 6-8. Command List (SYSTem Subsystem) Function Command Beep sound on/off SYST

Página 89

6.2 Command List APS-1102 Programmable AC/DC Power Source 6-7Table 6-10. Common Command List (Common Commands and Queries) Common Commands and Qu

Página 90

1.4 List of Functions APS-1102 Programmable AC/DC Power Source 1-41.4 List of Functions The main functions of the APS-1102 are listed below.

Página 91 -  phase

6.2 Command List APS-1102 Programmable AC/DC Power Source 6-8a) Input buffer  The number of commands that can be sent at one time is limited by t

Página 92 - 4.4.2 Sequence settings

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-96.3 Command Descriptions 6.3.1 Overview of Programming Language This product

Página 93

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-10b) SCPI data format All command messages and acknowledge messages sent to the

Página 94

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-11d) Subsystem commands Subsystem commands are commands used to execute the par

Página 95

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-122) Path separator The path separator (:) separates the current keyword from

Página 96

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-134) Implicit keywords Any keyword that is enclosed by square brackets ([ ])

Página 97 -  Operation step <1>

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-146.3.2 Detailed command descriptions The following describes various command

Página 98 - IncreaseDecrease

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-15 [SOURce:]CURRent:LIMit:PEAK:HIGH This sets the upper limit of the output p

Página 99 -  Operation step <2>

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-16 [SOURce:]FREQuency:LIMit:HIGH This sets the upper limit of the frequency t

Página 100 -  Operation steps

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-17 [SOURce:]MODE This sets the output mode. There are eight output modes, e

Página 101 -  Operation step

1.4 List of Functions APS-1102 Programmable AC/DC Power Source 1-5Table 1-2. List of Functions (2/2) Function Description External control

Página 102

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-18 [SOURce:]PHASe[:IMMediate] This sets the phase at the start of output. T

Página 103

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-19 [SOURce:]SEQuence:COUNt? This returns the jump times of the step specified

Página 104 -  Setting step 1

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-20 Type <NR2> Range 200.0 to 200.0 (400.0 to 400.0) Second par

Página 105 - Selection box

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-21 [SOURce:]SEQuence:TPARameter This sets the step transition parameters. T

Página 106 -  Setting step 2

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-22 [SOURce:]SEQuence:STEP Specifies the target step number for sequence editi

Página 107 - SEQUENCE

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-23 [SOURce:]VOLTage:LIMit:LOW This sets the upper limit of the output voltage

Página 108 - Output on/off LED is on

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-24d) MEASure subsystem  MEASure[:SCALar]:CURRent[:AC]? This returns the ou

Página 109

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-25 MEASure[:SCALar]:CURRent:AMPLitude:MAX? This returns the output current pe

Página 110 - Step number being executed

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-26 MEASure[:SCALar]:CURRent:HARMonic[:AMPLitude]? This returns the harmonic c

Página 111

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-27 MEASure[:SCALar]:POWer:AC:APParent? This returns the apparent power in VA

Página 112

This manual contains proprietary information, which is protected by copyrights. All rights are reserved. No part of this manual may be photocopied,

Página 113 - ENTERCANCEL

1.5 Operation Principles APS-1102 Programmable AC/DC Power Source 1-61.5 Operation Principles Figure 1-1 shows a block diagram of the APS-1102

Página 114 - External sync signal (TTL)

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-28 MEASure[:SCALar]:VOLTage[:AC]? This returns the output voltage RMS value (

Página 115

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-29 MEASure[:SCALar]:VOLTage:AVErage? This returns the output voltage average

Página 116

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-30f) STATus subsystem  STATus:OPERation:CONDition? This returns the operat

Página 117 - 4.8 Using Memory Functions

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-31 STATus:OPERation:NTRansition STATus:OPERation:PTRansition This sets the o

Página 118 - Indication on Control Panel

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-32 STATus:WARNing:ENABle This sets the warning event enable register. The se

Página 119

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-33g) OUTPut subsystem  OUTPut[:STATe] This controls on/off settings of the

Página 120

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-34i) TRACe subsystem  TRACe:CATalog? This returns a list of defined wavefo

Página 121 - CAUTION

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-35 TRACe:DELete[:NAME] This clears the specified arbitrary waveform memory.

Página 122

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-36 SYSTem:ERRor? This reads one error from the error queue (FIFO), and clears

Página 123 - Decrease

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-37 SYSTem:WRELease This clears a warning. When a warning is cleared, the SET

Página 124

APS-1102 Programmable AC/DC Power Source 2-12. PREPARATIONS BEFORE USE 2.1 Checking Before Use ················································

Página 125

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-38l) Common commands  CLS This clears the following registers.  Standa

Página 126

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-39 IDN? This returns the model name, etc. The response message includes the

Página 127 - 5. MENUS

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-40 RST This resets the device to its factory settings. However, reset canno

Página 128

6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-41 TST? This returns the self test results. In this device, “0” is always r

Página 129 - 5.1 Screen Configuration

6.4 Command Tree APS-1102 Programmable AC/DC Power Source 6-426.4 Command Tree The command tree for each of the APS-1102 subsystem is shown in Fig

Página 130

6.5 Status System APS-1102 Programmable AC/DC Power Source 6-436.5 Status System The APS-1102 includes the minimum set of status groups defined b

Página 131 - 5.1.1 Status icons

6.5 Status System APS-1102 Programmable AC/DC Power Source 6-446.5.1 Status byte The status byte register definitions are listed in Table 6-13. B

Página 132 - 5.1.3 Sequence display

6.5 Status System APS-1102 Programmable AC/DC Power Source 6-456.5.2 Standard event status The structure of the standard event status register is

Página 133 - 5.2.1 Menus

6.5 Status System APS-1102 Programmable AC/DC Power Source 6-46Table 6-14. Standard Event Status Register Definitions Bit Weight Description PON

Página 134

6.5 Status System APS-1102 Programmable AC/DC Power Source 6-476.5.3 Operation status The structure of the operation status register is shown in

Página 135

2.1 Checking Before Use APS-1102 Programmable AC/DC Power Source 2-22.1 Checking Before Use Before installing and using the APS-1102, make sure th

Página 136

6.5 Status System APS-1102 Programmable AC/DC Power Source 6-486.5.4 Warning status The structure of the warning status register is shown in Figu

Página 137

6.6 Error Message List APS-1102 Programmable AC/DC Power Source 6-496.6 Error Message List USB error messages are listed in Table 6-15 below. T

Página 138

6.7 Programming Precautions APS-1102 Programmable AC/DC Power Source 6-506.7 Programming Precautions a) Arbitrary waveform data Arbitrary wavefo

Página 139

APS-1102 Programmable AC/DC Power Source 7-17. TROUBLESHOOTING 7.1 Protection Function ·······················································

Página 140 - 5.2.6 Shortcut keys

7.1 Protection Function APS-1102 Programmable AC/DC Power Source 7-27.1 Protection Function The APS-1102 is equipped with a protection function th

Página 141 - 5.3 SET Menu

7.1 Protection Function APS-1102 Programmable AC/DC Power Source 7-3Table 7-1. Protection Function Protection Action When Detected Displayed Mes

Página 142 - 5.3.1 Output mode setting

7.2 Error Messages and Responses APS-1102 Programmable AC/DC Power Source 7-47.2 Error Messages and Responses The APS-1102 performs a self test at

Página 143

7.2 Error Messages and Responses APS-1102 Programmable AC/DC Power Source 7-57.2.1 Error at power-on The APS-1102 performs the following fault che

Página 144

7.2 Error Messages and Responses APS-1102 Programmable AC/DC Power Source 7-67.2.2 Protection function-related errors When a protection function-r

Página 145 - 5.3.6 Waveform settings

7.2 Error Messages and Responses APS-1102 Programmable AC/DC Power Source 7-7Protection Function”.) Table 7-3 lists error messages and actions wh

Página 146

2.2 Installation Environment APS-1102 Programmable AC/DC Power Source 2-32.2 Installation Environment Note the following precautions to ensure the

Página 147

7.2 Error Messages and Responses APS-1102 Programmable AC/DC Power Source 7-87.2.3 Panel operation errors Panel operation error messages are disp

Página 148 - 5.4 MEASURE Screen

7.2 Error Messages and Responses APS-1102 Programmable AC/DC Power Source 7-9Table 7-5. Panel Operation Errors (2/2) Error Message Cause and Ac

Página 149

7.2 Error Messages and Responses APS-1102 Programmable AC/DC Power Source 7-107.2.4 Warning messages When output is turned off due to an output er

Página 150

7.2 Error Messages and Responses APS-1102 Programmable AC/DC Power Source 7-11Protection Function”.) Figure 7-4. Screen Display When Warning Ha

Página 151

7.2 Error Messages and Responses APS-1102 Programmable AC/DC Power Source 7-12Table 7-7. Warning Messages (2/2) Message Cause and Action Requir

Página 152

7.3 When Fault Is Suspected APS-1102 Programmable AC/DC Power Source 7-137.2.5 USB-related external control errors Table 7-6 lists USB-related ex

Página 153 - 5.5 MISC Menu

7.3 When Fault Is Suspected APS-1102 Programmable AC/DC Power Source 7-14Table 7-9. When Fault Is Suspected (Problem when Switching Power on/off)

Página 154

7.3 When Fault Is Suspected APS-1102 Programmable AC/DC Power Source 7-15 Table 7-11. When Fault Is Suspected (Problem Related to Output Voltage

Página 155

7.3 When Fault Is Suspected APS-1102 Programmable AC/DC Power Source 7-16Table 7-13. When Fault Is Suspected (Problem Related to Output Error) Sy

Página 156

7.3 When Fault Is Suspected APS-1102 Programmable AC/DC Power Source 7-17Table 7-14. When Fault Is Suspected (Problem Related to Measurement Funct

Página 157 - 5.5.2 Memory (MEMORY)

2.2 Installation Environment APS-1102 Programmable AC/DC Power Source 2-4 Conditions of installation site  The APS-1102 should be used indoors,

Página 158

7.3 When Fault Is Suspected APS-1102 Programmable AC/DC Power Source 7-18Table 7-17. When Fault Is Suspected (Problem Related to Limiter Setting R

Página 159

APS-1102 Programmable AC/DC Power Source 8-18. MAINTENANCE 8.1 Introduction ··································································

Página 160

8.1 Introduction APS-1102 Programmable AC/DC Power Source 8-28.1 Introduction This chapter describes the following items.  Caution points and

Página 161

8.2 Routine Maintenance APS-1102 Programmable AC/DC Power Source 8-3b) When fan filter is dirty Two air filters are provided to filter out dust tha

Página 162 - 5.6 System Menu

8.3 Storage, Repackaging, and Transport APS-1102 Programmable AC/DC Power Source 8-48.3 Storage, Repackaging, and Transport Store the APS-1102 in

Página 163

8.4 Checking the Version Number APS-1102 Programmable AC/DC Power Source 8-58.4 Checking the Version Number The APS-1102 firmware version is displ

Página 164

8.4 Checking the Version Number APS-1102 Programmable AC/DC Power Source 8-64. Press the key to move the cursor to “INFORMATION”. ENTERCANC

Página 165

8.5 Backup Battery APS-1102 Programmable AC/DC Power Source 8-78.5 Backup Battery The contents of memory ( See “4.8 Using Memory Functions”) and

Página 167

APS-1102 Programmable AC/DC Power Source 9-19. SPECIFICATIONS 9.1 Output ······································································

Página 168

2.3 Grounding and Power Supply Connection APS-1102 Programmable AC/DC Power Source 2-5 Do not install the APS-1102 in the following locations: 

Página 169

9.1 Output APS-1102 Programmable AC/DC Power Source 9-2 Unless otherwise noted, the following conditions are adopted: Power input: 200 V AC, 50

Página 170

9.1 Output APS-1102 Programmable AC/DC Power Source 9-3 Output terminals Terminal block with M4 screws (rear panel) AC receptacle (universal typ

Página 171

9.1 Output APS-1102 Programmable AC/DC Power Source 9-4 Maximum output peak current 100 V range: 40 Apk 200 V range: 20 Apk Note 1: For

Página 172

9.1 Output APS-1102 Programmable AC/DC Power Source 9-5 Line regulation 0.2% or less (Power source input voltage is 100 V, 120 V, or 230 V, no lo

Página 173 - USB INTERFACE

9.2 Current Limiter APS-1102 Programmable AC/DC Power Source 9-69.2 Current Limiter  Output peak current limiter When limiter is operating, ou

Página 174 - 6.1 Setup for Use

9.4 Signal Sources APS-1102 Programmable AC/DC Power Source 9-79.4 Signal Sources The signal sources that can be selected are internal (INT), ext

Página 175 - 6.2 Command List

9.5 Measurement Functions APS-1102 Programmable AC/DC Power Source 9-89.5 Measurement Functions  Output voltage measurement RMS value: RMS

Página 176

9.5 Measurement Functions APS-1102 Programmable AC/DC Power Source 9-9 Output power measurement Effective power Full scale: 1200 W Di

Página 177

9.6 Sequence Function APS-1102 Programmable AC/DC Power Source 9-109.6 Sequence Function Output parameters can be changed abruptly or swept in se

Página 178

9.7 Arbitrary Waveform Memory APS-1102 Programmable AC/DC Power Source 9-119.7 Arbitrary Waveform Memory The contents of arbitrary waveform memor

Página 179

2.3 Grounding and Power Supply Connection APS-1102 Programmable AC/DC Power Source 2-6Frequency range: 50 Hz/60 Hz ±2 Hz (single phase) Power cons

Página 180

9.10 General APS-1102 Programmable AC/DC Power Source 9-129.10 General  LCD settings Contrast: Adjustable Display color: Blue background o

Página 181 - 6.3 Command Descriptions

9.11 External Control I/O APS-1102 Programmable AC/DC Power Source 9-139.11 External Control I/O  External control operation mode Enabled or d

Página 182 - 8-bit data byte

9.14 Withstand Voltage and Insulation Resistance APS-1102 Programmable AC/DC Power Source 9-149.14 Withstand Voltage and Insulation Resistance Be

Página 183 -  Current path

9.17 External Dimensions and Weight APS-1102 Programmable AC/DC Power Source 9-15 10 0 10 20 30 40 50 C Performance guarantee %RH9080706050403020

Página 184 - :SOUR:FREQ 1000

9.17 External Dimensions and Weight APS-1102 Programmable AC/DC Power Source 9-16 Figure 9-2. External Dimensions Cover labels Built-in air filte

Página 185

9.18 EC Declaration of Conformity APS-1102 Programmable AC/DC Power Source 9-179.18 EC Declaration of Conformity We GOOD WILL INSTRUMENT CO., LTD.

Página 186

2.3 Grounding and Power Supply Connection APS-1102 Programmable AC/DC Power Source 2-7 Connect the power in this order. 1. Make sure that the

Página 187

2.4 Simple Operation Checks APS-1102 Programmable AC/DC Power Source 2-82.4 Simple Operation Checks The following describes simple methods for che

Página 188

2.4 Simple Operation Checks APS-1102 Programmable AC/DC Power Source 2-92. Panel settings Set the APS-1102 as shown below. See “3.4 Main Operat

Página 189 -  [SOURce:]PHASe:CLOCk

APS-1102 Programmable AC/DC Power Source i Preface  Thank you for purchasing the APS-1102 programmable AC/DC power source. To ensure safe and pro

Página 190 -  [SOURce:]SEQuence:LEN?

2.5 Calibration APS-1102 Programmable AC/DC Power Source 2-102.5 Calibration To calibrate the APS-1102, contact Good Will or an authorized distrib

Página 191 -  [SOURce:]SEQuence:DELete

APS-1102 Programmable AC/DC Power Source 3-13. PANEL AND BASIC OPERATIONS 3.1 Panel Components and Operations ··································

Página 192

3.1 Panel Components and Operations APS-1102 Programmable AC/DC Power Source 3-23.1 Panel Components and Operations 3.1.1 Operation panel Numbers

Página 193

3.1 Panel Components and Operations APS-1102 Programmable AC/DC Power Source 3-33.1.2 Front panel Numbers shown after names in the following two

Página 194 -  [SOURce:]SEQuence:STEP

3.1 Panel Components and Operations APS-1102 Programmable AC/DC Power Source 3-43.1.3 Rear panel External signal input/external sync signal input

Página 195 -  [SOURce:]VOLTage:RANGe

3.2 Display and Initial Settings at Power-on APS-1102 Programmable AC/DC Power Source 3-53.2 Display and Initial Settings at Power-on  Display a

Página 196

3.2 Display and Initial Settings at Power-on APS-1102 Programmable AC/DC Power Source 3-6Table 3-2. Settings in Memory (2/2) Function Setting I

Página 197

3.3 I/O Terminals APS-1102 Programmable AC/DC Power Source 3-73.3 I/O Terminals 3.3.1 Output terminals (front and rear)  Connection to output o

Página 198

3.3 I/O Terminals APS-1102 Programmable AC/DC Power Source 3-8 Connection to output terminals (rear) Outputs are isolated from the input power lin

Página 199

3.3 I/O Terminals APS-1102 Programmable AC/DC Power Source 3-9 Connect cables to the output terminal block as described below. Outputs are isola

Página 200

APS-1102 Programmable AC/DC Power Source ii Safety Precautions  To ensure safe use, be sure to observe the following warnings and cautions. Good W

Página 201

3.3 I/O Terminals APS-1102 Programmable AC/DC Power Source 3-103.3.2 USB connector Use a commercial (off-the-shelf) USB cable to connect the rear

Página 202 -  STATus:OPERation[:EVENt]?

3.3 I/O Terminals APS-1102 Programmable AC/DC Power Source 3-113.3.3 External control I/O The APS-1102 is equipped with an (8-bit) external contro

Página 203 -  STATus:WARNing:CONDition?

3.3 I/O Terminals APS-1102 Programmable AC/DC Power Source 3-12Table 3-3. External Control I/O Connectors Pin No. I/O Function Remark 1 Output

Página 204 -  STATus:WARNing[:EVENt]?

3.3 I/O Terminals APS-1102 Programmable AC/DC Power Source 3-133.3.4 External signal input/external sync signal input terminal When using an extern

Página 205 -  INPut:GAIN

3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-143.4 Main Operation Example Main operations are described below in the follo

Página 206 -  TRACe[:DATA]

3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-153.4.1 Power on/off When the POWER switch is set to “|”, the power goes on,

Página 207 -  SYSTem:CONFigure:EXTIO

3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-16 Main operations screen is displayed. Figure 3-11. Example of Main

Página 208 -  SYSTem:TUNit

3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-173.4.2 Setting output mode The APS-1102 provides the eight output modes lis

Página 209 -  SYSTem:WRELease

3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-18 Operation steps Select output mode by selecting in the SET menu. 1.

Página 210 -  ESR?

3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-193.4.3 Setting output voltage range Select 100 V or 200 V. The output volt

Página 211 -  RCL

APS-1102 Programmable AC/DC Power Source iii ! ! !  Prevention of electrical shock due to output voltage The maximum output of the APS-1102 is

Página 212 -  STB?

3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-202. Press the ENTER key to display the selection box. ENTERCANCEL Selec

Página 213 -  WAI

3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-213.4.4 Setting waveform The APS-1102 allows to select a sine wave, square w

Página 214 - CONFigure

3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-223. Press the or key to move the cursor to the waveform to be output.

Página 215

3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-23 Operation steps To set the output voltage, set in the SET menu. 1.

Página 216 - 6.5.1 Status byte

3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-243.4.6 Setting output frequency The AC output frequency can be set in the f

Página 217

3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-253.4.7 Using limiter functions a) Using current limiter The APS-1102 includ

Página 218

3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-26 Operation steps Select the icon in the SET menu corresponding to the desi

Página 219 - 6.5.3 Operation status

3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-27b) Using setting range limiter The APS-1102 internal mode (AC-INT, AC+DC-IN

Página 220 - 6.5.4 Warning status

3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-283. Press the ENTER key to display the LIMIT screen . ENTERCANCEL 4.

Página 221 - 6.6 Error Message List

3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-293.4.8 Output on/off To turn the APS-1102 output on or off, simply press th

Página 222 - 6.7 Programming Precautions

APS-1102 Programmable AC/DC Power Source ivContents Preface  ...

Página 223 - TROUBLESHOOTING

3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-303.4.9 Using measurement functions The APS-1102 is equipped with the followi

Página 224 - 7.1 Protection Function

3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-31 Operation steps To select a measurement display, select “MEASURE” in the

Página 225

3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-324. Press the or key to move the cursor to the desired measurement displ

Página 226

3.5 Output Characteristics APS-1102 Programmable AC/DC Power Source 3-333.5 Output Characteristics The following charts show output voltage vs. ou

Página 227 - 7.2.1 Error at power-on

3.5 Output Characteristics APS-1102 Programmable AC/DC Power Source 3-34 Figure 3-15. Output Voltage vs. Output Current Characteristics (100 V AC I

Página 228

APS-1102 Programmable AC/DC Power Source 4-14. ADVANCED OPERATION EXAMPLE 4.1 Use as a DC Power Source ········································

Página 229

4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-24.1 Use as a DC Power Source When using the APS-1102 as a DC voltage sou

Página 230 - Message box

4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-3 Once a diode has been connected, a load that does not consume power keep

Página 231

4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-42. Press the ENTER key to display the selection box. ENTERCANCEL Sel

Página 232 - 7.2.4 Warning messages

4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-54.1.3 Setting the output voltage range Select 100 V or 200 V as the outpu

Página 233

Contents APS-1102 Programmable AC/DC Power Source v4.1.2 Selecting an output mode (AC+DC-INT mode) ...

Página 234

4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-63. Press the or key to move the cursor to 100 V or 200 V. ENTER

Página 235 - 7.3 When Fault Is Suspected

4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-74.1.4 Setting the output voltage The ranges that can be set are listed b

Página 236 - Keylock”

4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-83. Press the and keys to move the cursor to the digit to be changed,

Página 237

4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-94.1.5 Setting output frequency of superimposed AC To set the output frequ

Página 238

4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-104.1.6 Setting superimposed AC waveform Selects among 16 types of sine w

Página 239 - MEASURE

4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-114. Press the ENTER key to set the selected waveform. ENTERCANCEL

Página 240

4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-12b) Select measurement display Select one form among RMS, AVG, or PEAK as

Página 241 - MAINTENANCE

4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-134. Press the or key to move the cursor to the desired measurement d

Página 242 - 8.2 Routine Maintenance

4.2 Measurement of Inrush Current APS-1102 Programmable AC/DC Power Source 4-144.2 Measurement of Inrush Current 4.2.1 Inrush current In such an

Página 243

4.2 Measurement of Inrush Current APS-1102 Programmable AC/DC Power Source 4-154.2.2 Set phase at output on To set the phase at output on, select

Página 244

Contents APS-1102 Programmable AC/DC Power Source vi5.3.5 Output initial phase settings ...

Página 245

4.2 Measurement of Inrush Current APS-1102 Programmable AC/DC Power Source 4-164.2.3 Set measurement display to peak value Set the displayed curre

Página 246

4.2 Measurement of Inrush Current APS-1102 Programmable AC/DC Power Source 4-174. Press the TOP MENU key or the CANCEL key to return to the SET me

Página 247 - 8.5 Backup Battery

4.2 Measurement of Inrush Current APS-1102 Programmable AC/DC Power Source 4-182. Press the or key to move the cursor to “RESET Ipkh…”, then p

Página 248

4.3 Measurement of Harmonic Current APS-1102 Programmable AC/DC Power Source 4-194.3 Measurement of Harmonic Current Switching power sources are

Página 249 - SPECIFICATIONS

4.3 Measurement of Harmonic Current APS-1102 Programmable AC/DC Power Source 4-203. Press the or key to move the cursor to the harmonic order t

Página 250 - 9.1 Output

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-214.4 Using the Sequence Function 4.4.1 Sequence operations When the

Página 251 -  Maximum output current

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-22a) Sequence A sequence is comprised of a combination of at least two

Página 252

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-23The step transition parameters specify the next step and its timing.

Página 253 -  Output DC offset

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-24An example of basic step transitions is shown below. <START> O

Página 254 - 9.3 Setting Range Limits

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-25d) Sequence control The following describes how sequence operations a

Página 255 - 9.4 Signal Sources

Contents APS-1102 Programmable AC/DC Power Source vii7. TROUBLESHOOTING ...

Página 256 - 9.5 Measurement Functions

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-26e) Sequence loop Either an entire sequence or a block of any number o

Página 257 -  Output power measurement

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-27f) Step synchronized output The code that is specified in the step b

Página 258 - 9.6 Sequence Function

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-284.4.2 Sequence settings Sequence settings are made as described below

Página 259 - 9.9 Protection Functions

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-293. Press the ENTER key to display the SEQUENCE screen. ENTERCANC

Página 260 - 9.10 General

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-304.4.3 Programming sequences When “PROGRAM” is selected in the SEQUEN

Página 261 - 9.13 Power Input

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-31Table 4-8. Setting Items in PROGRAM Screen (1/3) Setting Name Item

Página 262 -  EMC Compliance

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-32Table 4-9. Setting Items in PROGRAM Screen (2/3) Setting Name Item

Página 263 -  Weight

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-33Table 4-10. Setting Items in PROGRAM Screen (3/3) Setting Name Item

Página 264

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-341. Open the SEQUENCE screen and display the PROGRAM screen. See “4

Página 265 - ◎ Safety

4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-35 Operation step <2> The settings for DC voltage operation type

Comentários a estes Manuais

Sem comentários