Programmable AC/DC Power Source APS-1102 USER MANUAL GW INSTEK PART NO. 82PS-11020M01 ISO-9001 CERTIFIED MANUFACTURER
APS-1102 Programmable AC/DC Power Source viiiFigures Figure 1-1. Block Diagram...
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-364.4.4 Control of sequence operations The CONTROL item in the SEQUENC
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-37b) When operating with the shortcut keys Operation step The contro
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-384.4.5 Clear sequence memory Data is saved to sequence memory automat
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-394.4.6 Example of sequence operation settings The following describes
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-40The operation steps are described below. Operation steps using c
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-416. Press the key to move the cursor to the line displaying “CONST”
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-42 Setting step 2 10. Press the or key to move the cursor to “STE
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-434.4.7 Execution of sequence operations Once sequence programming has
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-444. Press the ENTER key to display the selection box. ENTERCANCEL
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-458. Press the key to select “CONTROL”, then press the ENTER key to di
Figures APS-1102 Programmable AC/DC Power Source ixFigure 5-1. LCD Screen (When Normal) ...
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-46c) Operations after starting sequence When a sequence is started, the
4.5 Control Using External Control I/O Connector APS-1102 Programmable AC/DC Power Source 4-474.5 Control Using External Control I/O Connector Di
4.6 Output of Arbitrary Waveforms APS-1102 Programmable AC/DC Power Source 4-484.6 Output of Arbitrary Waveforms Arbitrary waveforms are generated
4.6 Output of Arbitrary Waveforms APS-1102 Programmable AC/DC Power Source 4-492. Press the or key to move the cursor to the arbitrary waveform
4.7 Synchronization of Output to External Signal APS-1102 Programmable AC/DC Power Source 4-504.7 Synchronization of Output to External Signal The
4.7 Synchronization of Output to External Signal APS-1102 Programmable AC/DC Power Source 4-514.7.1 External signal synchronization This functio
4.7 Synchronization of Output to External Signal APS-1102 Programmable AC/DC Power Source 4-524. Press the ENTER key to select the mode to be set.
4.8 Using Memory Functions APS-1102 Programmable AC/DC Power Source 4-534.7.2 Line synchronization This function synchronizes the output frequenc
4.8 Using Memory Functions APS-1102 Programmable AC/DC Power Source 4-54 Memory control is performed via the “MEMORY” screen. After selecting an o
4.8 Using Memory Functions APS-1102 Programmable AC/DC Power Source 4-55 Operation steps Select and then “MEMORY” in the MISC menu to store, re
APS-1102 Programmable AC/DC Power Source xTables Table 1-1. List of Functions (1/2) ...
4.8 Using Memory Functions APS-1102 Programmable AC/DC Power Source 4-564. Press the or key to select the operation to be performed. ENT
4.9 Amplification of External Signal APS-1102 Programmable AC/DC Power Source 4-574.9 Amplification of External Signal The APS-1102 can be used as
4.9 Amplification of External Signal APS-1102 Programmable AC/DC Power Source 4-58a) Possible voltage settings for output Operation steps Sele
4.9 Amplification of External Signal APS-1102 Programmable AC/DC Power Source 4-59the ENTER key. This sets the selected output voltage range.
4.9 Amplification of External Signal APS-1102 Programmable AC/DC Power Source 4-60b) Signal input The setup for external input is completed once th
4.10 Adding External Signals and Internal Signals APS-1102 Programmable AC/DC Power Source 4-614.10 Adding External Signals and Internal Signals
APS-1102 Programmable AC/DC Power Source 5-15. MENUS 5.1 Screen Configuration ·······················································
APS-1102 Programmable AC/DC Power Source 5-25.6.1 Keylock ········································································· 5-38 5.6.2 Beep s
5.1 Screen Configuration APS-1102 Programmable AC/DC Power Source 5-35.1 Screen Configuration The LCD on the control panel splits in m
Tables APS-1102 Programmable AC/DC Power Source xiTable 5-11. SET Menu Items and Output Modes ...
5.1 Screen Configuration APS-1102 Programmable AC/DC Power Source 5-4The following information is displayed in various parts of the screen. A:
5.1 Screen Configuration APS-1102 Programmable AC/DC Power Source 5-55.1.1 Status icons The status window displays status icons that indicate the
5.1 Screen Configuration APS-1102 Programmable AC/DC Power Source 5-65.1.2 Warnings and error messages When a warning or error occurs, an error
5.2 Basic Operations APS-1102 Programmable AC/DC Power Source 5-75.2 Basic Operations The APS-1102 basic operations are described below. 5.2.
5.2 Basic Operations APS-1102 Programmable AC/DC Power Source 5-8Table 5-3. Items in SET Menu Icon Item Reference Select output mode See “
5.2 Basic Operations APS-1102 Programmable AC/DC Power Source 5-9Table 5-4. Items in MISC Menu Setting Name Setting Reference SEQUENCE Open s
5.2 Basic Operations APS-1102 Programmable AC/DC Power Source 5-10Table 5-5. Items in SEQUENCE Menu Setting Name Setting Reference CONTROL...
5.2 Basic Operations APS-1102 Programmable AC/DC Power Source 5-11Table 5-7. Items in REMOTE Menu Setting Name Setting Reference LOCAL... S
5.2 Basic Operations APS-1102 Programmable AC/DC Power Source 5-125.2.2 Navigating the menu tree Use the UP and DOWN keys to move among items dis
5.2 Basic Operations APS-1102 Programmable AC/DC Power Source 5-135.2.3 Numerical value input operations When input of numerical values is requi
Tables APS-1102 Programmable AC/DC Power Source xiiTable 7-14. When Fault Is Suspected (Problem Related to Measurement Functions) ... 7
5.2 Basic Operations APS-1102 Programmable AC/DC Power Source 5-145.2.5 EXEC input The EXEC box is displayed for items to be actually executed b
5.3 SET Menu APS-1102 Programmable AC/DC Power Source 5-155.3 SET Menu The SET menu in the menu window is used to set basic functions. The ava
5.3 SET Menu APS-1102 Programmable AC/DC Power Source 5-165.3.1 Output mode setting Table 5-12 lists the eight output modes that can be selected
5.3 SET Menu APS-1102 Programmable AC/DC Power Source 5-17 Figure 5-7 shows a block diagram of the APS-1102 signal sources. Figure 5-7. Block
5.3 SET Menu APS-1102 Programmable AC/DC Power Source 5-185.3.3 Setting output voltage The output voltage settings listed below can be made for
5.3 SET Menu APS-1102 Programmable AC/DC Power Source 5-195.3.4 Setting output frequency This sets the AC voltage frequency. When either AC-SY
5.3 SET Menu APS-1102 Programmable AC/DC Power Source 5-205.3.7 Output peak current limiter settings The positive value and the negative value of
5.3 SET Menu APS-1102 Programmable AC/DC Power Source 5-215.3.8 Output average current limiter settings This limits the output average current.
5.4 MEASURE Screen APS-1102 Programmable AC/DC Power Source 5-225.4 MEASURE Screen The MEASURE screen in the measured value window displays meas
5.4 MEASURE Screen APS-1102 Programmable AC/DC Power Source 5-235.4.1 Output voltage measurement When “MEASURE” has been selected in the MISC me
APS-1102 Programmable AC/DC Power Source 1-11. OVERVIEW 1.1 General ...
5.4 MEASURE Screen APS-1102 Programmable AC/DC Power Source 5-245.4.2 Output current measurement When “MEASURE” has been selected in the MISC me
5.4 MEASURE Screen APS-1102 Programmable AC/DC Power Source 5-255.4.3 Output power measurement The output power values described below are alway
5.4 MEASURE Screen APS-1102 Programmable AC/DC Power Source 5-265.4.6 Output harmonic current measurement Output harmonic current measurement is
5.5 MISC Menu APS-1102 Programmable AC/DC Power Source 5-275.5 MISC Menu This menu is used to enter detailed settings for various functions. Th
5.5 MISC Menu APS-1102 Programmable AC/DC Power Source 5-28b) PROGRAM (sequence programming) This “PROGRAM” screen is used to program sequences.
5.5 MISC Menu APS-1102 Programmable AC/DC Power Source 5-29Table 5-21. PROGRAM Screen Items (2/3) Setting Name Item Operation FREQ AC frequen
5.5 MISC Menu APS-1102 Programmable AC/DC Power Source 5-30Table 5-22. PROGRAM Screen Items (3/3) Setting Name Item Operation STEP TERM Step
5.5 MISC Menu APS-1102 Programmable AC/DC Power Source 5-315.5.2 Memory (MEMORY) The “MEMORY” screen is used to control memory. Settings saved
5.5 MISC Menu APS-1102 Programmable AC/DC Power Source 5-325.5.3 Remote (REMOTE) The remote control connected via a USB interface can be used to
5.5 MISC Menu APS-1102 Programmable AC/DC Power Source 5-335.5.5 Setting range limiter (LIMIT) The setting range limiter indicates the LIMIT scre
1.1 General APS-1102 Programmable AC/DC Power Source 1-21.1 General The APS-1102 programmable AC/DC power source is a power source that can ou
5.5 MISC Menu APS-1102 Programmable AC/DC Power Source 5-345.5.6 Selection of measurement display (MEASURE) Select the measured values to be disp
5.5 MISC Menu APS-1102 Programmable AC/DC Power Source 5-355.5.8 Output on/off The APS-1102 output on/off setting can be entered using the OUTPU
5.6 System Menu APS-1102 Programmable AC/DC Power Source 5-365.6 System Menu This menu is used to enter the following system settings for the AP
5.6 System Menu APS-1102 Programmable AC/DC Power Source 5-373. Press the ENTER key to display the SYSTEM screen . ENTERCANCEL 4. Press t
5.6 System Menu APS-1102 Programmable AC/DC Power Source 5-385.6.1 Keylock The APS-1102 is equipped with a function that prevents key input error
5.6 System Menu APS-1102 Programmable AC/DC Power Source 5-395.6.2 Beep sound When the beep sound is on, a beep sounds when an incorrect operatio
5.6 System Menu APS-1102 Programmable AC/DC Power Source 5-405.6.3 LCD contrast adjustment The LCD screen contrast level can be set to any of 100
5.6 System Menu APS-1102 Programmable AC/DC Power Source 5-415.6.4 LCD display color setting The display color of the LCD screen on the control p
5.6 System Menu APS-1102 Programmable AC/DC Power Source 5-425.6.5 Time unit setting The unit used to indicate the time parameter can be specifie
5.6 System Menu APS-1102 Programmable AC/DC Power Source 5-435.6.6 Output on/off setting at power-on The APS-1102 can be set to automatically tur
1.3 Applications APS-1102 Programmable AC/DC Power Source 1-3 Enables AC-superimposed DC output When in the AC+DC mode, an AC wave (sine wav
5.6 System Menu APS-1102 Programmable AC/DC Power Source 5-445.6.7 External control input enable/disable setting External control input can be se
5.6 System Menu APS-1102 Programmable AC/DC Power Source 5-455.6.8 Reset function This function resets all basic settings to their initial (fact
APS-1102 Programmable AC/DC Power Source 6-16. USB INTERFACE 6.1 Setup for Use ·································································
6.1 Setup for Use APS-1102 Programmable AC/DC Power Source 6-26.1 Setup for Use The APS-1102 can be controlled under the USB Test and Measurement
6.2 Command List APS-1102 Programmable AC/DC Power Source 6-36.2 Command List The APS-1102 command list is shown in Table 6-1 to Table 6-9 and IEE
6.2 Command List APS-1102 Programmable AC/DC Power Source 6-4Table 6-2. Command List (MEASure Subsystem) Function Command Output current RMS valu
6.2 Command List APS-1102 Programmable AC/DC Power Source 6-5Table 6-4. Command List (STATus Subsystem) Function Command Operation condition regi
6.2 Command List APS-1102 Programmable AC/DC Power Source 6-6Table 6-8. Command List (SYSTem Subsystem) Function Command Beep sound on/off SYST
6.2 Command List APS-1102 Programmable AC/DC Power Source 6-7Table 6-10. Common Command List (Common Commands and Queries) Common Commands and Qu
1.4 List of Functions APS-1102 Programmable AC/DC Power Source 1-41.4 List of Functions The main functions of the APS-1102 are listed below.
6.2 Command List APS-1102 Programmable AC/DC Power Source 6-8a) Input buffer The number of commands that can be sent at one time is limited by t
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-96.3 Command Descriptions 6.3.1 Overview of Programming Language This product
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-10b) SCPI data format All command messages and acknowledge messages sent to the
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-11d) Subsystem commands Subsystem commands are commands used to execute the par
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-122) Path separator The path separator (:) separates the current keyword from
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-134) Implicit keywords Any keyword that is enclosed by square brackets ([ ])
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-146.3.2 Detailed command descriptions The following describes various command
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-15 [SOURce:]CURRent:LIMit:PEAK:HIGH This sets the upper limit of the output p
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-16 [SOURce:]FREQuency:LIMit:HIGH This sets the upper limit of the frequency t
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-17 [SOURce:]MODE This sets the output mode. There are eight output modes, e
1.4 List of Functions APS-1102 Programmable AC/DC Power Source 1-5Table 1-2. List of Functions (2/2) Function Description External control
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-18 [SOURce:]PHASe[:IMMediate] This sets the phase at the start of output. T
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-19 [SOURce:]SEQuence:COUNt? This returns the jump times of the step specified
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-20 Type <NR2> Range 200.0 to 200.0 (400.0 to 400.0) Second par
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-21 [SOURce:]SEQuence:TPARameter This sets the step transition parameters. T
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-22 [SOURce:]SEQuence:STEP Specifies the target step number for sequence editi
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-23 [SOURce:]VOLTage:LIMit:LOW This sets the upper limit of the output voltage
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-24d) MEASure subsystem MEASure[:SCALar]:CURRent[:AC]? This returns the ou
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-25 MEASure[:SCALar]:CURRent:AMPLitude:MAX? This returns the output current pe
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-26 MEASure[:SCALar]:CURRent:HARMonic[:AMPLitude]? This returns the harmonic c
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-27 MEASure[:SCALar]:POWer:AC:APParent? This returns the apparent power in VA
This manual contains proprietary information, which is protected by copyrights. All rights are reserved. No part of this manual may be photocopied,
1.5 Operation Principles APS-1102 Programmable AC/DC Power Source 1-61.5 Operation Principles Figure 1-1 shows a block diagram of the APS-1102
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-28 MEASure[:SCALar]:VOLTage[:AC]? This returns the output voltage RMS value (
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-29 MEASure[:SCALar]:VOLTage:AVErage? This returns the output voltage average
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-30f) STATus subsystem STATus:OPERation:CONDition? This returns the operat
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-31 STATus:OPERation:NTRansition STATus:OPERation:PTRansition This sets the o
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-32 STATus:WARNing:ENABle This sets the warning event enable register. The se
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-33g) OUTPut subsystem OUTPut[:STATe] This controls on/off settings of the
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-34i) TRACe subsystem TRACe:CATalog? This returns a list of defined wavefo
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-35 TRACe:DELete[:NAME] This clears the specified arbitrary waveform memory.
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-36 SYSTem:ERRor? This reads one error from the error queue (FIFO), and clears
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-37 SYSTem:WRELease This clears a warning. When a warning is cleared, the SET
APS-1102 Programmable AC/DC Power Source 2-12. PREPARATIONS BEFORE USE 2.1 Checking Before Use ················································
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-38l) Common commands CLS This clears the following registers. Standa
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-39 IDN? This returns the model name, etc. The response message includes the
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-40 RST This resets the device to its factory settings. However, reset canno
6.3 Command Descriptions APS-1102 Programmable AC/DC Power Source 6-41 TST? This returns the self test results. In this device, “0” is always r
6.4 Command Tree APS-1102 Programmable AC/DC Power Source 6-426.4 Command Tree The command tree for each of the APS-1102 subsystem is shown in Fig
6.5 Status System APS-1102 Programmable AC/DC Power Source 6-436.5 Status System The APS-1102 includes the minimum set of status groups defined b
6.5 Status System APS-1102 Programmable AC/DC Power Source 6-446.5.1 Status byte The status byte register definitions are listed in Table 6-13. B
6.5 Status System APS-1102 Programmable AC/DC Power Source 6-456.5.2 Standard event status The structure of the standard event status register is
6.5 Status System APS-1102 Programmable AC/DC Power Source 6-46Table 6-14. Standard Event Status Register Definitions Bit Weight Description PON
6.5 Status System APS-1102 Programmable AC/DC Power Source 6-476.5.3 Operation status The structure of the operation status register is shown in
2.1 Checking Before Use APS-1102 Programmable AC/DC Power Source 2-22.1 Checking Before Use Before installing and using the APS-1102, make sure th
6.5 Status System APS-1102 Programmable AC/DC Power Source 6-486.5.4 Warning status The structure of the warning status register is shown in Figu
6.6 Error Message List APS-1102 Programmable AC/DC Power Source 6-496.6 Error Message List USB error messages are listed in Table 6-15 below. T
6.7 Programming Precautions APS-1102 Programmable AC/DC Power Source 6-506.7 Programming Precautions a) Arbitrary waveform data Arbitrary wavefo
APS-1102 Programmable AC/DC Power Source 7-17. TROUBLESHOOTING 7.1 Protection Function ·······················································
7.1 Protection Function APS-1102 Programmable AC/DC Power Source 7-27.1 Protection Function The APS-1102 is equipped with a protection function th
7.1 Protection Function APS-1102 Programmable AC/DC Power Source 7-3Table 7-1. Protection Function Protection Action When Detected Displayed Mes
7.2 Error Messages and Responses APS-1102 Programmable AC/DC Power Source 7-47.2 Error Messages and Responses The APS-1102 performs a self test at
7.2 Error Messages and Responses APS-1102 Programmable AC/DC Power Source 7-57.2.1 Error at power-on The APS-1102 performs the following fault che
7.2 Error Messages and Responses APS-1102 Programmable AC/DC Power Source 7-67.2.2 Protection function-related errors When a protection function-r
7.2 Error Messages and Responses APS-1102 Programmable AC/DC Power Source 7-7Protection Function”.) Table 7-3 lists error messages and actions wh
2.2 Installation Environment APS-1102 Programmable AC/DC Power Source 2-32.2 Installation Environment Note the following precautions to ensure the
7.2 Error Messages and Responses APS-1102 Programmable AC/DC Power Source 7-87.2.3 Panel operation errors Panel operation error messages are disp
7.2 Error Messages and Responses APS-1102 Programmable AC/DC Power Source 7-9Table 7-5. Panel Operation Errors (2/2) Error Message Cause and Ac
7.2 Error Messages and Responses APS-1102 Programmable AC/DC Power Source 7-107.2.4 Warning messages When output is turned off due to an output er
7.2 Error Messages and Responses APS-1102 Programmable AC/DC Power Source 7-11Protection Function”.) Figure 7-4. Screen Display When Warning Ha
7.2 Error Messages and Responses APS-1102 Programmable AC/DC Power Source 7-12Table 7-7. Warning Messages (2/2) Message Cause and Action Requir
7.3 When Fault Is Suspected APS-1102 Programmable AC/DC Power Source 7-137.2.5 USB-related external control errors Table 7-6 lists USB-related ex
7.3 When Fault Is Suspected APS-1102 Programmable AC/DC Power Source 7-14Table 7-9. When Fault Is Suspected (Problem when Switching Power on/off)
7.3 When Fault Is Suspected APS-1102 Programmable AC/DC Power Source 7-15 Table 7-11. When Fault Is Suspected (Problem Related to Output Voltage
7.3 When Fault Is Suspected APS-1102 Programmable AC/DC Power Source 7-16Table 7-13. When Fault Is Suspected (Problem Related to Output Error) Sy
7.3 When Fault Is Suspected APS-1102 Programmable AC/DC Power Source 7-17Table 7-14. When Fault Is Suspected (Problem Related to Measurement Funct
2.2 Installation Environment APS-1102 Programmable AC/DC Power Source 2-4 Conditions of installation site The APS-1102 should be used indoors,
7.3 When Fault Is Suspected APS-1102 Programmable AC/DC Power Source 7-18Table 7-17. When Fault Is Suspected (Problem Related to Limiter Setting R
APS-1102 Programmable AC/DC Power Source 8-18. MAINTENANCE 8.1 Introduction ··································································
8.1 Introduction APS-1102 Programmable AC/DC Power Source 8-28.1 Introduction This chapter describes the following items. Caution points and
8.2 Routine Maintenance APS-1102 Programmable AC/DC Power Source 8-3b) When fan filter is dirty Two air filters are provided to filter out dust tha
8.3 Storage, Repackaging, and Transport APS-1102 Programmable AC/DC Power Source 8-48.3 Storage, Repackaging, and Transport Store the APS-1102 in
8.4 Checking the Version Number APS-1102 Programmable AC/DC Power Source 8-58.4 Checking the Version Number The APS-1102 firmware version is displ
8.4 Checking the Version Number APS-1102 Programmable AC/DC Power Source 8-64. Press the key to move the cursor to “INFORMATION”. ENTERCANC
8.5 Backup Battery APS-1102 Programmable AC/DC Power Source 8-78.5 Backup Battery The contents of memory ( See “4.8 Using Memory Functions”) and
APS-1102 Programmable AC/DC Power Source 9-19. SPECIFICATIONS 9.1 Output ······································································
2.3 Grounding and Power Supply Connection APS-1102 Programmable AC/DC Power Source 2-5 Do not install the APS-1102 in the following locations:
9.1 Output APS-1102 Programmable AC/DC Power Source 9-2 Unless otherwise noted, the following conditions are adopted: Power input: 200 V AC, 50
9.1 Output APS-1102 Programmable AC/DC Power Source 9-3 Output terminals Terminal block with M4 screws (rear panel) AC receptacle (universal typ
9.1 Output APS-1102 Programmable AC/DC Power Source 9-4 Maximum output peak current 100 V range: 40 Apk 200 V range: 20 Apk Note 1: For
9.1 Output APS-1102 Programmable AC/DC Power Source 9-5 Line regulation 0.2% or less (Power source input voltage is 100 V, 120 V, or 230 V, no lo
9.2 Current Limiter APS-1102 Programmable AC/DC Power Source 9-69.2 Current Limiter Output peak current limiter When limiter is operating, ou
9.4 Signal Sources APS-1102 Programmable AC/DC Power Source 9-79.4 Signal Sources The signal sources that can be selected are internal (INT), ext
9.5 Measurement Functions APS-1102 Programmable AC/DC Power Source 9-89.5 Measurement Functions Output voltage measurement RMS value: RMS
9.5 Measurement Functions APS-1102 Programmable AC/DC Power Source 9-9 Output power measurement Effective power Full scale: 1200 W Di
9.6 Sequence Function APS-1102 Programmable AC/DC Power Source 9-109.6 Sequence Function Output parameters can be changed abruptly or swept in se
9.7 Arbitrary Waveform Memory APS-1102 Programmable AC/DC Power Source 9-119.7 Arbitrary Waveform Memory The contents of arbitrary waveform memor
2.3 Grounding and Power Supply Connection APS-1102 Programmable AC/DC Power Source 2-6Frequency range: 50 Hz/60 Hz ±2 Hz (single phase) Power cons
9.10 General APS-1102 Programmable AC/DC Power Source 9-129.10 General LCD settings Contrast: Adjustable Display color: Blue background o
9.11 External Control I/O APS-1102 Programmable AC/DC Power Source 9-139.11 External Control I/O External control operation mode Enabled or d
9.14 Withstand Voltage and Insulation Resistance APS-1102 Programmable AC/DC Power Source 9-149.14 Withstand Voltage and Insulation Resistance Be
9.17 External Dimensions and Weight APS-1102 Programmable AC/DC Power Source 9-15 10 0 10 20 30 40 50 C Performance guarantee %RH9080706050403020
9.17 External Dimensions and Weight APS-1102 Programmable AC/DC Power Source 9-16 Figure 9-2. External Dimensions Cover labels Built-in air filte
9.18 EC Declaration of Conformity APS-1102 Programmable AC/DC Power Source 9-179.18 EC Declaration of Conformity We GOOD WILL INSTRUMENT CO., LTD.
2.3 Grounding and Power Supply Connection APS-1102 Programmable AC/DC Power Source 2-7 Connect the power in this order. 1. Make sure that the
2.4 Simple Operation Checks APS-1102 Programmable AC/DC Power Source 2-82.4 Simple Operation Checks The following describes simple methods for che
2.4 Simple Operation Checks APS-1102 Programmable AC/DC Power Source 2-92. Panel settings Set the APS-1102 as shown below. See “3.4 Main Operat
APS-1102 Programmable AC/DC Power Source i Preface Thank you for purchasing the APS-1102 programmable AC/DC power source. To ensure safe and pro
2.5 Calibration APS-1102 Programmable AC/DC Power Source 2-102.5 Calibration To calibrate the APS-1102, contact Good Will or an authorized distrib
APS-1102 Programmable AC/DC Power Source 3-13. PANEL AND BASIC OPERATIONS 3.1 Panel Components and Operations ··································
3.1 Panel Components and Operations APS-1102 Programmable AC/DC Power Source 3-23.1 Panel Components and Operations 3.1.1 Operation panel Numbers
3.1 Panel Components and Operations APS-1102 Programmable AC/DC Power Source 3-33.1.2 Front panel Numbers shown after names in the following two
3.1 Panel Components and Operations APS-1102 Programmable AC/DC Power Source 3-43.1.3 Rear panel External signal input/external sync signal input
3.2 Display and Initial Settings at Power-on APS-1102 Programmable AC/DC Power Source 3-53.2 Display and Initial Settings at Power-on Display a
3.2 Display and Initial Settings at Power-on APS-1102 Programmable AC/DC Power Source 3-6Table 3-2. Settings in Memory (2/2) Function Setting I
3.3 I/O Terminals APS-1102 Programmable AC/DC Power Source 3-73.3 I/O Terminals 3.3.1 Output terminals (front and rear) Connection to output o
3.3 I/O Terminals APS-1102 Programmable AC/DC Power Source 3-8 Connection to output terminals (rear) Outputs are isolated from the input power lin
3.3 I/O Terminals APS-1102 Programmable AC/DC Power Source 3-9 Connect cables to the output terminal block as described below. Outputs are isola
APS-1102 Programmable AC/DC Power Source ii Safety Precautions To ensure safe use, be sure to observe the following warnings and cautions. Good W
3.3 I/O Terminals APS-1102 Programmable AC/DC Power Source 3-103.3.2 USB connector Use a commercial (off-the-shelf) USB cable to connect the rear
3.3 I/O Terminals APS-1102 Programmable AC/DC Power Source 3-113.3.3 External control I/O The APS-1102 is equipped with an (8-bit) external contro
3.3 I/O Terminals APS-1102 Programmable AC/DC Power Source 3-12Table 3-3. External Control I/O Connectors Pin No. I/O Function Remark 1 Output
3.3 I/O Terminals APS-1102 Programmable AC/DC Power Source 3-133.3.4 External signal input/external sync signal input terminal When using an extern
3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-143.4 Main Operation Example Main operations are described below in the follo
3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-153.4.1 Power on/off When the POWER switch is set to “|”, the power goes on,
3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-16 Main operations screen is displayed. Figure 3-11. Example of Main
3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-173.4.2 Setting output mode The APS-1102 provides the eight output modes lis
3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-18 Operation steps Select output mode by selecting in the SET menu. 1.
3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-193.4.3 Setting output voltage range Select 100 V or 200 V. The output volt
APS-1102 Programmable AC/DC Power Source iii ! ! ! Prevention of electrical shock due to output voltage The maximum output of the APS-1102 is
3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-202. Press the ENTER key to display the selection box. ENTERCANCEL Selec
3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-213.4.4 Setting waveform The APS-1102 allows to select a sine wave, square w
3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-223. Press the or key to move the cursor to the waveform to be output.
3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-23 Operation steps To set the output voltage, set in the SET menu. 1.
3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-243.4.6 Setting output frequency The AC output frequency can be set in the f
3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-253.4.7 Using limiter functions a) Using current limiter The APS-1102 includ
3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-26 Operation steps Select the icon in the SET menu corresponding to the desi
3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-27b) Using setting range limiter The APS-1102 internal mode (AC-INT, AC+DC-IN
3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-283. Press the ENTER key to display the LIMIT screen . ENTERCANCEL 4.
3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-293.4.8 Output on/off To turn the APS-1102 output on or off, simply press th
APS-1102 Programmable AC/DC Power Source ivContents Preface ...
3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-303.4.9 Using measurement functions The APS-1102 is equipped with the followi
3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-31 Operation steps To select a measurement display, select “MEASURE” in the
3.4 Main Operation Example APS-1102 Programmable AC/DC Power Source 3-324. Press the or key to move the cursor to the desired measurement displ
3.5 Output Characteristics APS-1102 Programmable AC/DC Power Source 3-333.5 Output Characteristics The following charts show output voltage vs. ou
3.5 Output Characteristics APS-1102 Programmable AC/DC Power Source 3-34 Figure 3-15. Output Voltage vs. Output Current Characteristics (100 V AC I
APS-1102 Programmable AC/DC Power Source 4-14. ADVANCED OPERATION EXAMPLE 4.1 Use as a DC Power Source ········································
4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-24.1 Use as a DC Power Source When using the APS-1102 as a DC voltage sou
4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-3 Once a diode has been connected, a load that does not consume power keep
4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-42. Press the ENTER key to display the selection box. ENTERCANCEL Sel
4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-54.1.3 Setting the output voltage range Select 100 V or 200 V as the outpu
Contents APS-1102 Programmable AC/DC Power Source v4.1.2 Selecting an output mode (AC+DC-INT mode) ...
4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-63. Press the or key to move the cursor to 100 V or 200 V. ENTER
4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-74.1.4 Setting the output voltage The ranges that can be set are listed b
4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-83. Press the and keys to move the cursor to the digit to be changed,
4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-94.1.5 Setting output frequency of superimposed AC To set the output frequ
4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-104.1.6 Setting superimposed AC waveform Selects among 16 types of sine w
4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-114. Press the ENTER key to set the selected waveform. ENTERCANCEL
4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-12b) Select measurement display Select one form among RMS, AVG, or PEAK as
4.1 Use as a DC Power Source APS-1102 Programmable AC/DC Power Source 4-134. Press the or key to move the cursor to the desired measurement d
4.2 Measurement of Inrush Current APS-1102 Programmable AC/DC Power Source 4-144.2 Measurement of Inrush Current 4.2.1 Inrush current In such an
4.2 Measurement of Inrush Current APS-1102 Programmable AC/DC Power Source 4-154.2.2 Set phase at output on To set the phase at output on, select
Contents APS-1102 Programmable AC/DC Power Source vi5.3.5 Output initial phase settings ...
4.2 Measurement of Inrush Current APS-1102 Programmable AC/DC Power Source 4-164.2.3 Set measurement display to peak value Set the displayed curre
4.2 Measurement of Inrush Current APS-1102 Programmable AC/DC Power Source 4-174. Press the TOP MENU key or the CANCEL key to return to the SET me
4.2 Measurement of Inrush Current APS-1102 Programmable AC/DC Power Source 4-182. Press the or key to move the cursor to “RESET Ipkh…”, then p
4.3 Measurement of Harmonic Current APS-1102 Programmable AC/DC Power Source 4-194.3 Measurement of Harmonic Current Switching power sources are
4.3 Measurement of Harmonic Current APS-1102 Programmable AC/DC Power Source 4-203. Press the or key to move the cursor to the harmonic order t
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-214.4 Using the Sequence Function 4.4.1 Sequence operations When the
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-22a) Sequence A sequence is comprised of a combination of at least two
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-23The step transition parameters specify the next step and its timing.
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-24An example of basic step transitions is shown below. <START> O
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-25d) Sequence control The following describes how sequence operations a
Contents APS-1102 Programmable AC/DC Power Source vii7. TROUBLESHOOTING ...
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-26e) Sequence loop Either an entire sequence or a block of any number o
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-27f) Step synchronized output The code that is specified in the step b
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-284.4.2 Sequence settings Sequence settings are made as described below
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-293. Press the ENTER key to display the SEQUENCE screen. ENTERCANC
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-304.4.3 Programming sequences When “PROGRAM” is selected in the SEQUEN
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-31Table 4-8. Setting Items in PROGRAM Screen (1/3) Setting Name Item
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-32Table 4-9. Setting Items in PROGRAM Screen (2/3) Setting Name Item
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-33Table 4-10. Setting Items in PROGRAM Screen (3/3) Setting Name Item
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-341. Open the SEQUENCE screen and display the PROGRAM screen. See “4
4.4 Using the Sequence Function APS-1102 Programmable AC/DC Power Source 4-35 Operation step <2> The settings for DC voltage operation type