Copyright 2003 GOODWILL INSTRUMENT CO., LTD.
MEASure FREQuency SToP <value<unit>
>
500 Set the stop frequency Range: From 9k to 2.7GHz. Unit can be kHz,
MHz and GHz
MEAS:FREQ:STP^200^MHz
OK
MEASure FREQuency SToP? 500 Query the stop frequency in kHz MEAS:FREQ:STP?
200000.0^kHz
MEASure FREQuency StepSize <value>
<unit>
1000 Set the step size of the frequency
settings
Range: From 0 to 2.7GHz. Unit can be kHz, MHz
and GHz
MEAS:FREQ:SS^10MHz
OK
MEASure FREQuency StepSize? 500 Query the step size of frequency
settings
MEAS:FREQ:SS?
10000.0^kHz
MEASure SPAN <index>
<unit>
500 Set Span Sets span from 0 to 2.7GHz in index 0 to 21.
0=Zero Span, 1=1kHz, 2=2kHz, 3=5kHz,
4=10kHz, 5=20kHz, 6=50kHz, 7=100kHz,
8=200kHz, 9=500kHz, 10=1MHz, 11=2MHz,
12=5MHz, 13=10MHz, 14=20MHz, 15=50MHz,
16=100MHz, 17=200MHz, 18=500MHz,
19=1GHz, 20=2GHz, 21=2.5GHz,22=Full Span.
MEAS:SPAN^9 (set the span to
1MHz)
OK
MEASure SPAN FULL 2000 Set span to full span
MEAS:SAPN:FULL
OK
MEASure SPAN ZERO 2000 Set span to zero span
MEAS:SPAN:ZERO
OK
MEASure SPAN LAST 200 Set span back to last span
MEAS:SPAN:LAST
OK
MEASure SPAN? 500 Query SPAN
MEAS:SPAN?
OK
MEASure REFLevel <value>
<reflvlunit>
1000 Set reference level +20 dBm to -50 dBm or
127 dBuV to 57 dBuV or
67 dBmV to -3 dBmV or
-12.9 dBm/Hz to -82.9 dBm/Hz @ 3k RBW
-22.9 dBm/Hz to –92.9 dBm/Hz @ 30k RBW
-32.9 dBm/Hz to –102.9 dBm/Hz @ 300k RBW
-44.1 dBm/Hz to –114.1 dBm/Hz @ 4M RBW
The unit has to be identical to the unit in use.
Otherwise the error message will appear.
MEAS:REFL^0^dBm
OK
MEAS:REFL^107^dBuV
OK
MEASure REFLevel? 500 Query reference level MEAS:REFL?
-30^dBm
MEASure REFLevel SCALE <value> 1000 Set amplitude scale 10, 5, 2, 1 MEAS:REFL:SCAL^5
OK