PSM SERIES PROGRAMMABLE POWER SUPPLY
PROGRAMMER MANUAL
35
6) :VOLTage:TRIGgered? MIN returns the lowest programmable
triggered voltage level.
:MEASure:C URRent?
Function:
Read the actual output current.
Syntax:
:MEASure:CURRent?
Returns:
Scientific mark
Examples:
:MEASure:CURRent? might return +1.23400000E+00 to indicate that
the load is drawing 1.2340 A(PSM-2010).
:MEASure?
Function:
Read the actual output voltage.
Syntax:
:MEASure?
Returns:
Scientific mark
Examples:
:MEASure? might return +1.15500000E+01 to indicate the voltage output
is 11.5500V(PSM-2010).
PSM SERIES PROGRAMMABLE POWER SUPPLY
PROGRAMMER MANUAL
36
:CURRent:PROTection
Function:
Set the overcurrent protection value.
Syntax:
:PROTection:CURRent {<Decimal numbers>|MIN|MAX}
Examples:
:CURRent:PROTection 10 sets the overcurrent protection value to
10.000A(PSM-2010).
:CURRent:PROTection MIN sets the overcurrent protection value to
0.000A(PSM-2010).
:CURRent:PROTection MAX sets the overcurrent protection value to
22.000A(PSM-2010). Please refer to Table1-1, Table1-2 and Table1-3.
:CURRent:PROTection?
Function:
Query the overcurrent protection value.
Syntax:
:CURRent:PROTection? [MIN|MAX]
Returns:
Scientific mark
Examples:
:CURRent:PROTection? will return the overcurrent protection value.
:CURRent:PROTection? MIN will return 0.
:CURRent:PROTection? MAX will return the highest programmable current
values. Please refer to Table1-1, Table1-2 and Table1-3.