GDS-1000A-U Programming Manual
52
:MEASure:ROVShoot
Query
Description
Returns rise overshoot amplitude in percentage.
Same as: Measure key F1~F5 F3 (ROVShoot)
Syntax
< Long >
< Short >
:measure:rovshoot?
:meas:rovs?
Returns
<NR2> with % sign
Note
Before using this command, select the
measurement channel. See the example below.
Example
:measure:source 1
:measure:rovshoot?
Selects Channel 1, and
then measures the rise
overshoot.
:MEASure:RPReshoot
Query
Description
Returns rise overshoot amplitude in percentage.
Same as: Measure key F1~F5 F3 (RPReshoot)
Syntax
< Long >
< Short >
:measure:rpreshoot?
:meas:rpr?
Returns
<NR2> with % sign
Note
Before using this command, select the
measurement channel. See the example below.
Example
:measure:source 1
:measure:rpreshoot?
Selects Channel 1, and
then measures the rise
preshoot.
:MEASure:SOURce
Set
Query
Description
Selects the measurement channel.
Same as: Measure key F1~F5 F1, F2