DC MILLI-OHM METER
PROGRAMMER MANUAL
26
Returns:
0/1
Examples:
:CONFigure:AUTo 1
Set to auto-range mode.
If it is in the auto-range mode, the command of :CONFigure:AUTo? Will
return the value of 1.
:CONFigure:RANGe?(query only)
Function:
Query the range of the present function, total 10 letters.
Syntax:
:CONFigure:RANGe?
Returns:
<String>
Examples:
:CONFigure:RANGe? might return “+3.0000E+2” to indicate the 300Ω
range, return unit is ohm.
:CONFigure:FUNCtion?(query only)
Function:
Return the present selected function.
DC MILLI-OHM METER
PROGRAMMER MANUAL
27
Syntax:
:CONFigure:FUNCtion?
Returns:
<String>
Examples:
:CONFigure:FUNCtion? might return “OHM” to indicate the present
ohm function.
Please refer to the returned message for every function as follows:
Table 6-2:
Function Description
Temperature compensation TC
Resistance OHM
Temperature TEMP
:CONFigure:RESistance(no query form)
Function:
Set ohm function and the range.
Syntax:
:CONFigure:RESistance <NR2>
Examples:
:CONFigure: RESistance 0 sets to ohm function and auto-range.
:CONFigure: RESistance 18 sets to ohm function and 30Ω range.
<NR2> is in ohm unit.