Gw-instek PSU-Series Programming User Manual Manual do Utilizador Página 77

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 128
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 76
REMOTE CONTROL
77
Example
CURR:EXT:RANG?
LOW
Returns LOW range.
[:SOURce]:CURRent:EXTernal:SOURce
Set
Query
Description
Sets whether constant current will be controlled
externally or not. Note: the setting will only be
valid after the power has been cycled.
Syntax
[:SOURce]:CURRent:EXTernal:SOURce
{NONE|VOLTage}
Query Syntax
[:SOURce]:CURRent:EXTernal:SOURce?
Parameter/Return
parameter
NONE
External control is not used.
VOLTage
External control is used.
Example
CURR:EXT:SOUR?
NONE
External control is not used.
[:SOURce]:CURRent[:LEVel][:IMMediate]
[:AMPLitude]
Set
Query
Description
Sets or queries the current level in amps. For
externally set current levels (from the analog
control connector) the set current level is returned.
Syntax
[:SOURce]:CURRent[:LEVel][:IMMediate][:AMPLitude]
{<NR2>(A)|MINimum|MAXimum}
Query Syntax
[:SOURce]:CURRent[:LEVel][:IMMediate][:AMPLitude]?
Parameter/Return
parameter
<NR2>
0~105% of the rated current output level.
MIN
Minimum current level.
MAX
Maximum current level.
Example
SOUR:CURR:LEV:IMM:AMPL?
38.000
Returns the current level in amps.
Vista de página 76
1 2 ... 72 73 74 75 76 77 78 79 80 81 82 ... 127 128

Comentários a estes Manuais

Sem comentários