COMMAND DETAILS
85
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:NWIDth?
4.995E-04
Selects Channel 1, and then measures the negative
pulse width.
:MEASure:PDUTy
Description
Returns the positive duty cycle ratio as percentage.
Syntax
:MEASure:PDUTy{?}
Related
commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the positive duty ratio.
Chan Off
Indicates the source channel is not
activated.
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:PDUTy?
5.000E+01
Selects Channel 1, and then measures the positive
duty cycle.
:MEASure:PERiod
Description
Returns the period.
Syntax
:MEASure:PERiod{?}
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the period.