Example
:MATH:FFT:SOURce CH1
Sets the FFT math source as channel 1.
:MATH:FFT:SOURce?
CH1
Return the FFT math source as channel 1.
:MATH:FFT:MAG
Set
Query
Description
Sets FFT vertical units as linear or decibels.
Syntax
:MATH:FFT:MAG {LINEAR|DB|?}
Parameter
LINEAR
Linear units (Vrms)
DB
Logarithmic units (dB)
Return parameter
Returns the FFT vertical units.
Example
:MATH:FFT:MAG DB
Sets FFT vertical units are dB.
:MATH:FFT:WINDow
Set
Query
Description
Sets the windowing filter used for the FFT
function.
Syntax
:MATH:FFT:WINDow
{RECTangular|HAMming|HANning|BLAckman|?}
Parameter
RECTangular
Rectangular window
HAMming
Hamming window
HANning
Hanning window
BLAckman
Blackman window
Return parameter
Returns the FFT window.
Example
:MATH:FFT:WINDow HAMming
Sets the FFT window filter to hamming.