COMMAND DETAILS
91
EITher
Sets the triggering point as either
stays high or stays low.
Example
:TRIGger:TIMEOut:WHEn HIGH
Sets the triggering point to when the signal stays
high.
:TRIGger:TIMEOut:TIMER
Set
Query
Description
Sets or queries the timeout trigger timer settings
(in seconds).
Note: Only applicable for 500MHz models with the
Timeout trigger APP installed.
Syntax
:TRIGger:TIMEOut:TIMER {<NRf> | ?}
Related
commands
:TRIGger:TIMEOut:WHEn
Parameter/
Return parameter
<NRf>
Time out time in seconds.
(10nS~10.0S)
Example
:TRIGger:TIMEOut:TIMER 1.00e+1
Sets the timeout time to 10 seconds.
System Commands
:SYSTem:LOCK {OFF|ON|?} .......................................91
:SYSTem:LOCK {OFF|ON|?}
Set
Query
Description
Turns the panel lock on off.
Syntax
:SYSTem:LOCK {OFF|ON|?}
Parameter
OFF
System lock off
ON
System lock on
Return parameter
Returns the status of the panel lock (ON, OFF).