Gw-instek PEL-2000 Series Programming User Manual Manual do Utilizador Página 109

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 170
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 108
COMMAND DETAILS
109
Query Example
:RES:STAT:HIGH:RISE?
MIN
0.8000
For high range CR mode,
the minimum value for
the rising slew rate is 0.8
A/uS for the specific
channel.
:RESistance:DYNamic:LOW:L1/L2
Channel Specific
Command
Description
Sets the low range resistance levels (Level 1 & 2)
for CR dynamic mode.
Syntax
:RESistance:DYNamic:LOW:L1/L2 <NRf+>[OHM]
Parameter
NRf+[OHM]
Ohms
L1 10
Sets L1 to 10 ohms. (low
range only)
L2 20OHM
Sets L2 to 20 ohms. (low
range only)
L1/L2 MIN
Sets L1 or L2 to the
minimum level for the
specific channel.
L1/L2 MAX
Sets L1 or L2 to the
maximum Level for the
specific channel.
Example
:RES:DYN:LOW:L1 10
In low range CR
dynamic mode, Set L1
(level 1) to 10 ohms.
Query Syntax
:RESistance:DYNamic:LOW:L1/L2? [MIN|MAX]
Return Parameter
<NR2> [MAX|MIN]
Resistance
1 unit= 1 ohm
Returns the resistance of
L1/L2.
Query Example
:RES:DYN:LOW:L2? MAX
300
Returns the maximum
resistance allowed for
the channel. (PEL-2020)
Vista de página 108
1 2 ... 104 105 106 107 108 109 110 111 112 113 114 ... 169 170

Comentários a estes Manuais

Sem comentários