Gw-instek PEL-3000 Series Programming Manual Manual do Utilizador Página 127

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 174
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 126
COMMNAND OVERVIEW
125
:FSEQuence:EDIT:END?
Set
Query
Description
Returns the number of points in the sequence.
Query Syntax
:FSEQuence:EDIT:END?
Return parameter
<NR1>
1~1000
Query example
:FSEQuence:EDIT:END?
> 20
Indicates that there are 20 steps in the sequence.
:FSEQuence[:DELet]:ALL
Set
Description
Deletes all the data points for the fast sequence.
Syntax
:FSEQuence[:DELet]:ALL
Example
:FSEQuence:ALL
:FSEQuence[:EDIT]:FILL
Set
Query
Description
The FILL function is used to evenly fill up the
current or resistance value settings from a starting
step to a finishing step. This function is equivalent
to entering the FUNC>Sequence>Fast
Sequence>Edit Sequence>Fill menu.
Syntax
:FSEQuence[:EDIT]:FILL
{<NR2>,<NR2>,<NR1>,<NR1>}
Query Syntax
:FSEQuence[:EDIT]:FILL?
Related
Commands
:FSEQuence:EDIT
Vista de página 126
1 2 ... 122 123 124 125 126 127 128 129 130 131 132 ... 173 174

Comentários a estes Manuais

Sem comentários