PEL-3000 Programming Manual
80
Example
:RESistance:VA MIN
Sets the resistance value to the minimum.
Query example
:RESistance:VA?
> 0
Returns the “A Value” conductance setting(MHO).
:RESistance:VB
Set
Query
Description
Sets or queries the CR mode “B Value” resistance.
This command is applicable to static mode only.
Note: A different value can be set for each current
range (High/Mid/Low).
Syntax
:RESistance:VB {<NRf>[ MHO ] | MINimum |
MAXimum }
Query Syntax
:RESistance:VB?
Parameter
<NRf>[ MHO ]
“B Value” conductance
value
MINIMUM or MIN
Minimum conductance
level
MAXIMUM or MAX
Maximum conductance
level
Return parameter
<NR2>
Returns the “B Value”
conductance value.
Example
:RESistance:VB MIN
Sets the resistance value to the minimum.
Query example
:RESistance:VB?
> 0
Returns the “B Value” conductance setting(MHO).
:RESistance:SRATe
Set
Query
Description
Sets or queries the current slew rate for CR static
mode.