PEL-3000 Programming Manual
92
:POWer:VB
Set
Query
Description
Sets or queries the CP mode “B Value” power. This
command is only applicable to static mode.
Note: A different “B Value” can be set to different
current ranges.
Syntax
:POWer:VB {<NRf>[ W ] | MINimum | MAXimum }
Query Syntax
:POWer:VB?
Parameter
<NRf>[W]
“B Value” power value
MINIMUM or MIN
Minimum power level
MAXIMUM or MAX
Maximum power level
Return parameter
<NR2>
Returns the “B Value”
power value.
Example
:POWer:VB MIN
Sets the power value to the minimum.
Query example
:POWer:VB?
>10W
Returns the “B Value” power setting.
:POWer:L1
Set
Query
Description
Sets or queries the CP mode “Level1” power. This
command is applicable to dynamic mode only.
Note: A different “Level1 value can be set for
different current ranges.
Syntax
:POWer:L1 {<NRf>[ W ] | MINimum | MAXimum }
Query Syntax
:POWer:L1?
Parameter
<NRf>[ W ]
“Level1” power value
MINIMUM or MIN
Minimum power level
MAXIMUM or MAX
Maximum power level
Return parameter
<NR2>
Returns the “Level1”
power value.