PEL-3000 Programming Manual
38
Query example
:INPut:SHORt?
>0
Indicates that the short function is off.
:INPut:MODE
Set
Query
Description
Selects the load function mode.
Syntax
:INPut:MODE{ LOAD|PROG|NSEQ|FSEQ }
Query Syntax
:INPut:MODE?
Parameter/
Return parameter
LOAD
Sets the load to generator
as a CC/CV/CP/CR load.
PROG
Sets the function mode to
program.
NSEQ
Sets the function mode to
Normal Sequence mode.
FSEQ
Sets the function mode to
Fast Sequence mode.
Example
:INPut:MODE PROG
Puts the load generator into Program mode.
Query example
:INPut:MODE?
>PROG
Indicates that the current function mode is Program.