Gw-instek GSP-930 Programming Manual Manual do Utilizador Página 125

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 195
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 124
REMOTE CONTROL
123
Parameter
<ampl>
<NRf> power or voltage
Return parameter
<NR3>
Example
:ACPR: HLIM -3.0e+1
[:SENSe]:ACPR:LLIMit
Set
Query
Description
Sets or queries the low limit for the main channel.
Used with ACPR measurement.
Syntax
[:SENSe]:ACPR:LLIMit <ampl>
Query Syntax
[:SENSe]:ACPR:LLIMit?
Parameter
<ampl>
<NRf> power or voltage
Return parameter
<NR3>
Example
:ACPR:ACH1:LLIM -5.0e+1
[:SENSe]:ACPR:HELP:STATe
Set
Description
Turns the on-screen help on/off.
Syntax
[:SENSe]:ACPR:HELP:STATe {OFF|ON|0|1}
Parameter
0
Turn help off.
1
Turn help on.
OFF
Turn help off.
ON
Turn help on.
Example
:ACPR:HELP:STAT ON
[:SENSe]:ACPR:SPACe
Set
Query
Description
Sets or queries the channel spacing between the
main channels.
Syntax
[:SENSe]:ACPR:SPACe <freq>
Query Syntax
[:SENSe]:ACPR:SPACe?
Vista de página 124
1 2 ... 120 121 122 123 124 125 126 127 128 129 130 ... 194 195

Comentários a estes Manuais

Sem comentários