GSP-930 Programming Manual
148
[:SENSe]:SEMask:OFFSet<n>:ADDition:
FREQuency:STARt?
Query
Returns the start frequency (refered to the center)
of the selected offset for the additional
requirements of the selected 3GPP SEM test.
[:SENSe]:SEMask:OFFSet<n>:ADDition:
FREQuency:STARt?
<n>
Offset 1 to 5
<NR3>
Start frequency in Hz
:SEM:OFFS1:ADD:FREQ:STAR?
>2.5e+6
[:SENSe]:SEMask:OFFSet<n>:ADDition:
FREQuency:STOP?
Query
Returns the stop frequency (refered to the center)
of the selected offset for the additional
requirements of the selected 3GPP SEM test.
[:SENSe]:SEMask:OFFSet<n>:ADDition:
FREQuency:STOP?
<n>
Offset 1 to 5
<NR3>
Stop frequency in Hz
:SEM:OFFS1:ADD:FREQ:STOP?
>3.5e+6