Questionable Status SEM Limit Register
Overview
The Questionable Status SEM Limit Register
Group indicates if any of the SEM offset limits
have been tripped.
Bit Summary
Bit
Weight
Description
0
1
Offset 1 Upper Fail: This bit is set to 1
when the SEM Offset 1 upper limit has
been violated.
1
2
Offset 1 Lower Fail: This bit is set to 1
when the SEM Offset 1 lower limit has
been violated.
2
4
Offset 2 Upper Fail: This bit is set to 1
when the SEM Offset 2 upper limit has
been violated.
3
8
Offset 2 Lower Fail: This bit is set to 1
when the SEM Offset 2 lower limit has
been violated.
4
16
Offset 3 Upper Fail: This bit is set to 1
when the SEM Offset 3 upper limit has
been violated.
5
32
Offset 3 Lower Fail: This bit is set to 1
when the SEM Offset 3 lower limit has
been violated.
6
64
Offset 4 Upper Fail: This bit is set to 1
when the SEM Offset 4 upper limit has
been violated.
7
128
Offset 4 Lower Fail: This bit is set to 1
when the SEM Offset 4 lower limit has
been violated.
8
256
Offset 5 Upper Fail: This bit is set to 1
when the SEM Offset 5 upper limit has
been violated.
9
512
Offset 5 Lower Fail: This bit is set to 1
when the SEM Offset 5 lower limit has
been violated.